Free download Scania VCI 2 VCI 3 software SDP3 2.31.1 on Mega: (tested)
https://mega.nz/#!Dd1gTbKT!oY2Z4uNUtneIRf5DGZdPWhZAQR3rfNaN0LsEFl9HZww
Scania SDP3 2.31 download: (Win7 64 bit,WIN 10 32/64 bit)
https://mega.nz/#!DYExVD7Y!Z7vVu-KB6hwABJ8LOyYeyd4VyhuI7w6nAqsVDYUzbrw
Password: cimi
Scania SDP3 2.30 download free:
https://mega.nz/#!dcU3WLJL!iNjRAo_zKbkEoI0ArlBoXfcBvRvrLlKlB7IJnqN6SLo
No pass!
Scania SDP3 2.31 test report: successful, safe to use
Note 1: without USB dongles
Note 2: SDP3 2.31 activation help with professionals at carobd.de
Test result: Scania SDP3 latest version 2.31.1 is verified to work no issues and is released on 09/07/2017: (works perfect)
http://www.carobd.de/wholesale/newest-scania-vci-2-sdp3-for-trucks-buses.html
Scania SDP3 2.31.1 system requirements:
Windows 7 32 bit, Windows 8/8.1 32 bit, Windows 10 32 bit.
■Microsoft .Net Framework 4.6.2 must be installed.
• There is no longer support for Windows 7 32 bit. For more information, see Ti 00-17 01 25.
Scania SDP3 2.31.1 features:
Function view
By using the search box at the top of the window you can now search directly in the function view. You can choose to search in the Adjustment, Check or Calibration tab.
Troubleshooting
The procedure for defect reporting in SDP3 has been improved to make it simpler to follow.
Instead of a guide in several steps, there is now a simple dialogue box. In the dialogue box you can select if you want to save the defect report locally or if you want to send it via e-mail. To be able to send the defect report via e-mail you must have Microsoft Outlook. You can choose to create a defect report for a specific individual product or to make a general defect report.
The dialogue box for defect reports you find in the Help menu.
Note: As from SDP3 2.31, the dialogue box is no longer available for use if you are connected to a job type. Scania CV AB 2017
Communication troubleshooting
• The instructions& solution for communication errors has been updated. You access the document via the Help menu.
System specifications
CUI –Infotainment system
• Support resume an interrupted download of software has been introduced.
COO – Coordinator
• The new guide verify and check switch modules in the steering wheel according to the version and the vehicle’s SOPS file.
EMS – Engine Management System
• Vehicles with the S8 engine control unit have previously lacked support for Default setting of power take-off adaptation. This has now been rectified.
• The Spark check guide has been removed for vehicles of the P, G, R and S series with Euro 6 gas engine. As the support in SDP3 has been improved, the guide tool is no longer required. Instead, use the Electrical system view for troubleshooting.
RES – Rechargeable energy storage system
• For the sake of clarity and uniformity, the hybrid battery has been changed to propulsion battery in all instances in SDP3.
TMS – Transmission management system
• New parameters have be added to TMS2:
o Clutch monitoring
o Downhill speed control with active prediction
o Reduced use of the clutch (new values) Scania CV AB 2017
• After a product update of the transmission management system, the Accelerometer adaptation must always be run. It now starts automatically after an update of the control unit.
GMS – Gearbox management system
• A function guide which shows how the power is transferred in the gearbox for different gears in real time has been added. You can also see how the gear shift forks move and which sleeves are affected.
The guide applies to the following gearboxes:
o GRS905
o GRS905R
o GRSO905
o GRSO905R
o GRSO925
o GRSO925R
o GRSO935
o GRSO936R
The guide also applies to the following transmission management systems:
o OPC4,
o OPC5
o TMS1
o TMS2
CMS – Chassis management system
• A guide for bleeding control circuit 2 has been implemented.
• Circuits, I/Os and the functional description of differential locks has been improved.
TSS/TSA – Tag axle steering system
• Function guides for activating and deactivating service mode have been implemented. Scania CV AB 2017
• A function guide for checking EST and ESTA has been implemented.
• A new parameter for the centring function has been implemented.
Scania SDP3 2.31.1 car list:
To work with Scania VCI2: can support vehicles after the year 1995:
Scania P, G, R, T, buses Scania series K, N, and other vehicles using engines Scania
To work with Scania VCI3: support vehicles after the year 2004:
trucks, buses and other heavy vehicles, which produces the corporation Scania
In short, Only hardware difference, they can use the same software
Scania vci 3 diagnostic tool highlights its high-speed WI-FI connection
Scania diagnostic codes:
000 00 No Fault
01 001 less than the rated voltage – heater works
02 002 higher than the rated voltage – heater works
004 03 Short circuit fan (D2I)
005 05 Short-circuiting the wires from alarm (D2I)
009 09 Heater off system TRS (D2I / D9W)
010 0A higher than the nominal voltage (heater stopped)
011 0B voltage less than the nominal (heater stopped)
012 0C overheat – fuel pump is turned off
013 0D temperature sensor recorded a high temperature
014 0E big difference values of t. sensor. overheating sensor. regulation. t (D3W / D9W)
015 0F heater overheated many times – the heater is turned off (D2I / D9W)
017 11 Reusable overheating (t exceeds the second threshold) (D3W)
020 14 Candle / rod defective bulbs
021 15 Short candle / bar bulbs
022 16 Faulty relays candle / bar bulbs (D2W)
023 17 Internal defect relay control R2 candle / bar bulbs
024 18 Short-circuit switch controller candle / bar bulbs
025 19 Short-circuit diagnostic socket
029 1D fan air gap 5 does not operate R3
030 1E air fan does not work in all positions (R3-D3W)
031 1F air fan does not work in all positions (R3-D3W)
032 20 Air fan does not work in all positions (R3-D3W)
033 21 Air fan does not work in all positions (R4-D2I / D9W)
034 22 there is no contact with the solenoid valve of the cooling system. (D2W / D9W)
035 23 No contact with the relay average performance
036 24 Short-circuit relay average performance
037 25 Do not rotate water pump (D2W / D9W)
038 26 No contact with the fan relay cab heating (D2W / D9W)
039 27 Short cab heating fan relay (D2W / D9W)
040 28 Short circuit solenoid. valve cooling system. (D2W / D9W)
042 2A Short circuit water pump (D9W)
043 2B Short cable from the computer to the heater fuel pump (D9W)
047 2F Short circuit of the fuel pump
048 30 No contact with the fuel pump
050 32 Heater run many times but have not worked (relay R3)
051 33 Flames emerged immediately after pressing the start button heater
052 34 No start (restart purge)
053 35 Stop flame during startup
36 054 Stop flame position max. productivity
055 37 Stop the flame in a position average performance
056 38 Stop the flame in the position of poor performance
057 39 Flame sensor short circuit (photoresist)
058 3A heater is turned off, but the flame in the combustion chamber (D2W)
059 3B Water temperature rising too quickly (D9W)
060 3C No contact with the sensor temperature control
061 3D sensor short circuit temperature control
062 3E No contact with the potentiometer (D2H / D2I)
3F 063 Short potentiometer (D2H / D2I)
064 40 No contact with flame sensor
065 41 Flame sensor short circuit
071 47 No contact with the sensor overheating (D3W / D9W)
072 48 Short-circuit overheating sensor (D3W / D9W)
073 49 Overheating sensor recorded the fastest increase in temperature (D9W)
090 5A Spontaneous error
091 5B high surge (high-voltage wires, CB-radio, etc.)
092 5C Faulty heater control unit – fault ROM
093 5D Faulty heater control unit – faulty RAM
094 5E Faulty heater control unit – fault EEPROM
096 60 Temperature sensor faulty heater ECU (D2I)
097 61 Faulty heater ECU (D2I / D2W / D9W)
255 FF cleared but faulty memory EEPROM