Xhorse MINI Plus II Conductivity Issue
1 , Remove those those screws for take off machine screen
2, Pull out the whole motor to expose the whole motor case and remove those screws to take off motor case
3 , After remove the motor case , the cable which related conductivity it will expose , please check if that cable has any damaged
4.This cable go though whole mian motor, one side connect with led bar and one side connect with probe base ,for remove that cable it need to remove the cable socket and then pull it out from bottom led bar side .
5.Loosen the fixing screw of the conductive wire as shown above and remove the LED lamp cover.
6.Remove the three fixing screws, note that there are three black plastic parts on the screws, do not lose
7.Check if the four wires are broken or if the screws are tightened.