Tag Archive | flex korhex

Flex Update Hyundai Kia SIM2K-510 ECU by OBD (Exclusive Solution)

SIM2K-510 New Exclusive Solution is coming !

New protocol released in Magic MotorSport Flex software version 8.28.0.0 allowing techniancians to program kefico SIM2K-510 units in OBD, following a simple, fast, and more efficient procedure.

Connect, read, modify!

Just connect the OBD cable, down.oad the Virtual Read and start your modifications. If the Virtual Read is unavailable, perform a real read in OBD on Bench mode. The unit will unlock automatically.

Moreover, even CAN FD versions are now supported thanks to the new FLX4.4 adapter

Vehicles: Hyundai ‘ Kia

Working mode: OBD’ OBD on Bench

SOftware: Flex 8.28.0.0

Connection: ~30 seconds

Reading time: ~ 5minutes

Writing time: ~10 minutes

Memories : VR/Read/Write/Checksum Maps

License: FLS0.1M/S FLS0.5M/S

Mode 01 OBD
Connect, read and edit

A simple and fast procedure

01. Connect the OBD cable
02. Download the Virtual Read.
03. Make the changes you need.

Mode 02 OBD on Bench

On the bench, with a real read

When the Virtual Read is not available.

Use OBD on Bench mode to perform a real read of the ECU

Also supports CAN-FD versions.

For versions using CAN-FD communication, Requires the new CAN-FD FLX4.4 adapter

Some of the supported vehicles.

Hyundai Kona (I) OS (2017MY) 1.6L CRDI 16V MHEV 134HP

Hyundai Tucson (IV) NX4(2020MY) 1.6I CRDI 16V 114HP

Kia Ceed(III) CD(2018MY) 1.6L CRDI 16V 134HP

Kia Sportage (V) NQ5(2021MY) 1.6L CRDI 16V MHEV 134HP

Kia Stonic(I) YB(2017MY) 1.6L CRDI 16V 114HP

 

Before Working on a SIM2K-510, CHECK the car and disconnect.

any external alarm system connected to the CAN bus
any SCR/Adblue emulator connected to the CAN bus
any OEM multimedia system connected to the CAN bus
any other device connected to the CAN bus that is not original equipment of the car
if any of these devices is connected, communication breaks and the ECU is permanently bricked. It cannot be recovered

Other precautions

Use a stabilised power supply( about 13v). The unlock does not start below 12.5v
Never interrupt the unlock. The Flex asks for confirmation before starting.
Keep the internet connection active for the whole operation.
CAN-FD versions: writing requires the new CAN-FD adapter FLX4.4 . With a secure Gateway(SGW detected), connect directly to the ECU (OBD on Bench)

Flex Korhex RED Flashing LED Solution

Problem:

One of the Flex users had a problem connecting Korhex adapter for unlocking ECU.
Software shows Connected
But the RGB LED near the USB/power connector keeps flashing RED continuously.


Solution:
The flashing red LED does not necessarily mean there is a fault

The red flashing LED is normal: the Korhex stays red when it is idle(as when it arrives) and turns green only during a Connect that is at least partly successful.

It can simply mean that Korhex is connected but not currently engaged with a locked ECU.

It does not mean the tool is faulty.

The red light will flash until you open a protocol that needs Korhex. Once you open a protocol that needs Korhex, the light will become green and when it is actually glitching it’ll become blue.

That’s normal until you open the protocol for glitching and then it will change to green.

How to Active MagicMotorsport Korhex Tool ?

Does MagicMotorsport Korhex require activation ?
Yes, Korhex requires activation.

How to active Korhex ?
The activation process is straightforward and follows these steps:
Open the Magic Motorsport Flex software and click on “Help Desk” to go to the Magic Motorsport portal.


Click“Add Tool” and select Korhex

Input the serial number into the Magic Motorsport Flex portal to add the tool to your account.
Where to find the serial number ?
1. In the email MMS sent you after the purchase
2. On the back of the Korhex device unit
3. On the invoice related to the purchase.

Once actived, you can access the Korhex option on the left-hand side of the Flex software, which displays important about the tool. In the top right corner, you wil find a tutorial with images

For more informations about Korhex ,please contact Jenny from www.carobd.de

Whatsapp: +86 19947637411
Email: Sales@Carobd.de

Flex Korhex Stuck on Boot Glitch Process Page Solution

Problem:
Tried to boot Glitch unlock a VAG MD1CS004 H80 ECU with Korhex. Flex reads ECU ID, but nothing happens. Flex software is stuck on the Glitch process page. Any solution?

Solution:

Sometime you need to move Korhex
Move Korhex until you find the right spot !

If not working, abort operation.
If its over glitching.
Turn everything off.
Unplug everything.
Even pins.
Start again.
Allow program to boot and make sure you have 3 green or 2 green and one blue light on top left.
If needs update, update flex.
Then reconnect everything.
Place korhex central to plate.
Wabble plate in a square if it touches edge nudge it central
Make sure your E1 connector is on or off in manual on flex and follow instructions.
If it doesn’t read or connect email support on ticket.